SUPER GL easy / SUPER GL easy+

The well known analysers of the product line SUPER G were developed for clinical laboratory. With the SUPER GL speedy an analyser was developed which uses the modern technology of the sensors together with other new technical items. So the SUPER GL speedy has besides a innovative sample rotor for 60 samples a new touch screen for easy operating the device in menu choosing and together with both news also the well known biosensor.

As with all analysers using the enzymatic-amperometric measuring principle, pre-analysis is quite simple. Only a few µl of capillary blood are needed, taken from the finger berry using an end-to-end or open-end-capillary. These samples are diluted using a defined amount of solution in a sample cup and hemolysed, and can then be measured immediately. Approximately one minute after taking the blood, you have the result.

All devices provide the technical standard necessary for modern analysers, such as a variety of EDP links, barcode reader, storage function for the samples and controls etc.

We realised the IFCC - recommendation for displaying the glucose values plasma referenced at the SUPER GL easy+.

Please note that the order form is not available via the mobile version. Alternatively, you can use the order form as a PDF.

Performance Data

Measuring Time

Single Measurement Glucose ca. 40 seconds
Single Measurement Glucose / Lactate / Hemoglobin ca. 75 seconds

Measuring Range

Glucose 0.5 mmol/l to 50 mmol/l or 9 mg/dl to 900.8 mg/dl
Lactate 0.5 mmol/l to 30 mmol/l or 4.5 mg/dl to 270 mg/dl
Hemoglobin 1.86 mmol/l to 15.52 mmol/l or 3 g/dl to 25 g/dl

Sample Volume

10 µl sample diluted with 500 µl hemolysate solution

Precision (20 samples) - Variation Coefficient Indication

Glucose (12 mmol/l or 216 mg/dl) < 2.0 %
Lactate (10 mmol/l or 90 mg/dl) < 2.5 %
Hemoglobin (7.6 mmol/l or 12 g/dl) < 2.0 %

Sensors

Operating Time Glucose Sensor max. 6 months / max. 10.000 samples
Operating Time Glucose and Lactate Sensors max. 3 months / max. 10.000 samples

Technical Specifications

Working Temperatur + 15 °C bis + 35 °C
Supply Voltage 12 V DC
Power Consumption max. 45 W
Classification according MPG In-vitro-Diagnosticum (guidline 98/79/EC)

Interfaces

Printer serial, RS 232
EDP serial, RS 232
Barcode Reader external, PS/2

Dimensions / Weight

Width 220 mm
Hight 170 mm
Depth 185 mm
Weight 1.7 kg
General data
Sensors
QuantityItem numberItem descriptionDevice(s)
Washing solution
QuantityItem numberItem descriptionDevice(s)
Reagent cartidges
QuantityItem numberItem descriptionDevice(s)
Hemolysate-System-Solution
QuantityItem numberItem descriptionDevice(s)
Control material
QuantityItem numberItem descriptionDevice(s)
Glucocapil reaction cups
QuantityItem numberItem descriptionDevice(s)
Capillaries
QuantityItem numberItem descriptionDevice(s)
Glucocapil calibration solution
QuantityItem numberItem descriptionDevice(s)
Miscellaneous
QuantityItem numberItem descriptionDevice(s)
Sets
QuantityItem numberItem descriptionDevice(s)
Print order form

Documents

Declarations of conformity